Module features:

1.Can achieve fast and frequent turn-on and off the circuit, an unlimited times of switching.

2.The on-off process does not produce noise, no spark, no electromagnetic interference.

3.Longer life than conventional electromagnetic relays.

4.Using dual MOS parallel active output, lower internal resistance, more current, power is strong, to meet the use of most equipment.

5.Emergency stop function (STOP key), with reverse protection, reverse does not burn.

6.Sleep mode, if there is no operation within 5 minutes, the display will be turned off automatically, press any button will wake it up.

7.You can set different OP, CL, LOP parameters,these parameters are independent of each other and are saved separately.

Applicatio

Used to control the motor, light bulbs, LED lights, DC motors, micro pumps, solenoid valves and so on,through this module, you can easily control these devices

Specificatio

1.Operating voltage: DC 5V - 36V

2.Trigger signal source: High level trigger(DC 3.0V 24V)

3.Output voltage: DC 5V-36V

4.Output power: 400W

5.Output current: 15A (continuous, under room temperature.The max. current can up to 30A)

6.Quiescent Current: 15mA

7.Working temperature: -40-85 ℃

8.Size: 6.0×3.4×1.2cm

Note:

1. The module is an active output, the output voltage is equal to the input voltage (DC 5-36V).

2.The poles of 'DC + 'and' load + 'are internal short connected, but the poles of ' DC- 'and' load - 'poles cannot be shorted, otherwise, the load cannot be controlled on or off, which means the load is always energized

Operating mode:

P1 mode: After the signal is triggered, the relay turns on for OP time and then turns off; within OP time, the following operations

P1.1: The signal triggers invalid again

P1.2: The signal is triggered again to retime

P1.3: The signal triggers reset again, the relay is disconnected, and the timing is stopped;

P1.4: Power-on delay without triggering

P-2: Give the trigger signal, after the relay is turned off CL time, the relay is turned on OP time, after the timing is completed, the relay is turned off;

P3.1: Give the trigger signal, after the relay turns on the OP time, the relay turns off the CL time, and then loops the above actions, and the signal is given again in the loop, the relay is turned off, and the timing is stopped; the number of cycles (LOP) can be set;

P3.2: No trigger signal is required after power-on, the relay turns on the OP time, the relay turns off the CL time, and the above actions are cycled; the number of cycles (LOP) can be set;

P-4: Signal hold function If there is a trigger signal, the timing is cleared, and the relay remains on; when the signal disappears, the relay is turned off after the timing OP; when there is another signal during the timing, the timing is cleared;

Product parameters:

1: Working voltage: DC 5V--36V;

2: Trigger signal source: high-level trigger (DC 3.0V-24V) signal ground and system ground are not common ground to improve the anti-interference ability of the system (you can also short-circuit the common ground by yourself)

3: Output capacity: DC DC 5V-36V, continuous current 15A at normal temperature, power 400W! Under auxiliary cooling conditions, the maximum current can reach 30A.

4: Quiescent current: 15mA

5: Service life: unlimited switching; working temperature: -40-85 ℃; size: 6.0*3.4*1.2cm

6: With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit board, set parameters will be remembered forever after power off.

Pay attentio

The module is an active live output, and the voltage at the output (load) is equal to the voltage at the input (DC 5V-36V).

The'DC+' and load'+' poles are internally short-circuited, but the'DC-' and load'-' poles cannot be short-circuited during use, otherwise the load will not be controlled to be turned on and off, which is equivalent to the load being It's always powered.

Timing range

0.1 seconds (minimum) ~ 999 minutes (maximum) continuously adjustable

How to choose the timing range:

After setting the parameter value in the mode selection interface, select the timing range by short pressing the STOP key;

XXX. Decimal point is in one place, timing range: 1 second to 999 seconds

XX.X Decimal point is in the tenth place, timing range: 0.1 second ~ 99.9 seconds

X.X.X. Full decimal point, timing range: 1 minute to 999 minutes

For example, if you want to set the OP to 3.2 seconds, then move the decimal point to the tenth digit, the digital tube displays 03.2

Parameter descriptio OP on time, CL off time, LOP cycle times (1-999 times, "---" stands for infinite cycles)

These parameters are independent of each other, but these parameters are shared by all modes. For example, when the on-time OP is set to 5 seconds in P1.1, and the user wants to switch to P1.2 mode, then enter P1.2 to set the corresponding parameters, OP It will also be 5 seconds;

In the main interface (display 000), short press SET button, it will display OP (CL, LOP) and the corresponding time XXX;

If there is only OP (for example P1.1, P1.2, P1.3) time in the mode, then short press the SET button will only display the OP and the corresponding time;

If there are OP, CL, LOP in the mode (such as mode P3.1, P3.2), short press SET button will display OP and corresponding time, CL and corresponding time, LOP and corresponding times;

After setting the mode, you can easily view the parameters set in the current mode by pressing the SET button on the main interface, which is very convenient!

How to set parameters

1. First determine the working mode of the relay;

2. According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current working mode (default P1.1 mode), and then enter the main interface,) "Long press the SET button for 2 seconds and release "Enter the mode selection interface, select the mode to be set (P1.1~P-4) by short pressing the UP and DOWN buttons;

3. After selecting the mode to be set (for example, P3.2), short press SET to set the corresponding parameters, then the parameters to be set will flash (OP ON time, CL OFF time, LOP cycle number ("-- -" stands for infinite cycles)), adjust the parameter value through UP and DOWN, support long press (fast increase or decrease) and short press (increase or decrease by 1 unit); after setting the parameter value, short press the STOP key To select the decimal point position, select the timing range (the corresponding time is 0.1 seconds to 999 minutes); short press the SET button to set the next parameter of the current mode, the process is the same as above;

4. After setting the parameters of the selected mode, long press the SET button for 2 seconds and then release, the currently set mode will flash, and then return to the main interface, setting the parameters successfully, very simple!

Main interface: "000" (no decimal point) is displayed when the relay is not working, and the decimal point is very clear when the relay is working!

Mode selection interface: long press SET button to enter, after setting is completed, long press SET button to exit, return to the main interface, very simple!

STOP button function expansio

Relay enable mode:

1. ON: The relay is allowed to be turned on during the ON time of the OP;

2. OFF: The relay is forbidden to conduct and is always off;

Press the STOP button on the main interface to switch between ON and OFF. The current state will flash and then return to the main interface. (This function is an emergency stop function, a key to open and close the relay)

Sleep mode:

1. C-P sleep mode: within five minutes, without any operation, the digital tube automatically turns off the display and the program runs normally;

2. O-d normal mode: the digital tube is always on and displayed;

Press and hold the STOP button for 2 seconds and then release it to switch between the C-P and O-d states. The current state will flash and then return to the main interface.

상품필수 정보

품명 및 모델명 상품상세참조##상품상세참조
KCC 인증 필 유무
정격전압, 소비전력, 에너지소비효율등급 상품상세참조##상품상세참조##상품상세참조
동일모델의 출시년월 상품상세참조
제조자, 수입품의 경우 수입자를 함께 표기 상품상세참조
제조국 또는 원산지 해당없음
크기, 무게 상품상세참조##상품상세참조
주요 사양 상품상세참조
품질보증기준 상품상세참조
A/S 책임자와 전화번호 상품상세참조

배송안내

기본 배송료 안내 

 

- 테크 선전 (TechShenzhen.com)의 상품 배송은 대한민국내 배송 방식으로 진행됩니다. 

  a.  대한민국내 기본배송료는 2,700원 입니다. (도서,산간,오지 일부지역은 배송비가 추가될 수 있습니다)

  b. 80,000원 이상 구매시 무료배송입니다.  

 

 

배송 시간 안내 

 

- 테크 선전 (TechShenzhen.com)의 평균 배송일은 아래와 같습니다.

 a. 대한민국내 재고 상품의 배송은 평균 2일입니다. 

 b. 자체 제작 제품의 경우 시간이 2~10일이 더 소요될 수 있습니다. 

 

교환 및 반품안내

- 상품 택(tag)제거 또는 개봉으로 상품 가치 훼손 시에는 상품수령후 7일 이내라도 교환 및 반품이 불가능합니다.

- 저단가 상품, 일부 특가 상품은 고객 변심에 의한 교환, 반품은 고객께서 배송비를 부담하셔야 합니다(제품의 하자,배송오류는 제외)

- 일부 상품은 신모델 출시, 부품가격 변동 등 제조사 사정으로 가격이 변동될 수 있습니다.

- 신발의 경우, 실외에서 착화하였거나 사용흔적이 있는 경우에는 교환/반품 기간내라도 교환 및 반품이 불가능 합니다.

- 수제화 중 개별 주문제작상품(굽높이,발볼,사이즈 변경)의 경우에는 제작완료, 인수 후에는 교환/반품기간내라도 교환 및 반품이 불가능 합니다. 

- 수입,명품 제품의 경우, 제품 및 본 상품의 박스 훼손, 분실 등으로 인한 상품 가치 훼손 시 교환 및 반품이 불가능 하오니, 양해 바랍니다.

- 일부 특가 상품의 경우, 인수 후에는 제품 하자나 오배송의 경우를 제외한 고객님의 단순변심에 의한 교환, 반품이 불가능할 수 있사오니, 각 상품의 상품상세정보를 꼭 참조하십시오. 

환불안내

대한민국에서 판매되는 상품 


  -  상품 청약철회 가능기간은 상품 수령일로 부터 7일 이내 입니다. 

  -  대한민국 상법이 보장하는 구매자와 판매자의 권리를 준수합니다.

 

AS안내

대한민국내 재화에 대한 A/S 

- 소비자분쟁해결 기준(공정거래위원회 고시)에 따라 피해를 보상받을 수 있습니다.

- A/S는 판매자에게 문의하시기 바랍니다.

 

 

해외 구매 재화에 대한 A/S 

- 테크 선전은 해외 셀러의 판매 제품에 대한 A/S는 판매자에게 문의하는 것을 원칙으로 합니다. 

- 테크 선전은 제품의 현격한 문제, 배송시 파손 및 훼손으로 인한 문제에 대해서는 운영자로서 양 당사자의 분쟁에 적극 개입합니다.

- 테크 서전은 배송과 훼손에 대한 처리 과정에서 추가적인 비용이 발생할 경우, 구매자에게 청구할 수 있습니다.

 

이미지 확대보기스마트팜 DC 타이머 릴레이 모듈 DC12-24V 1채널

스마트팜 DC 타이머 릴레이 모듈 DC12-24V 1채널
  • 스마트팜 DC 타이머 릴레이 모듈 DC12-24V 1채널
닫기

비밀번호 인증

글 작성시 설정한 비밀번호를 입력해 주세요.

닫기

장바구니 담기

상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?

찜 리스트 담기

상품이 찜 리스트에 담겼습니다.
바로 확인하시겠습니까?

스크롤 좌측 배너
스크롤 우측 배너
상단으로 이동